YSLCY | Intrinsically Safe PVC Control Cable for Intrinsically Safe Circuits with Copper Braiding and Blue Outer Sheath
Item descriptions
Application: | For dry, humid and wet locations as well as areas with explosion hazard, but not in the open-air. To be used as an MSR cable for the application in intrinsically safe circuits. The copper braiding optimises protection against external electrical and magnetic interferences. The cable is suitable for medium-level mechanical stress. |
Construction: | 1.....fine-stranded bare copper 2.....core insulation of polyvinylchloride (PVC) 3.....braiding of tinned copper wires 4.....outer sheath of polyvinylchloride (PVC), blue, increased oil resistant |
Standards: | adapted to DIN VDE 0281 DIN EN 60228 class 5 (construction) core identification JZ: 1 core green/yellow, other cores black with figures core identification OZ: every core black with figures |
Nominal voltage Uo/U | [V] | 300 / 500 Volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -5°C till +70°C | |
fixed | -30°C till +70°C | ||
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 10 |
Bending radius | in motion | x diameter | 20 |
Flammability | standard | EN 60332-1-2 |
Number of cores and nominal cross section mm² | Copper figure kg/km | Cond. construction (appr. value) mm | Overall diameter appr. mm | Weight appr. kg / km |
2 x 0,75 | 41,28 | 24 x 0,21 | 6,2 | 56 |
3 x 0,75 | 49,92 | 24 x 0,21 | 6,5 | 70 |
4 x 0,75 | 58,56 | 24 x 0,21 | 7,0 | 96 |
5 x 0,75 | 69,12 | 24 x 0,21 | 7,8 | 157 |
7 x 0,75 | 85,44 | 24 x 0,21 | 8,4 | 168 |
12 x 0,75 | 132,48 | 24 x 0,21 | 10,9 | 231 |
18 x 0,75 | 202,56 | 24 x 0,21 | 12,8 | 314 |
25 x 0,75 | 268,80 | 24 x 0,21 | 15,2 | 434 |
2 x 1,5 | 62,40 | 30 x 0,26 | 7,1 | 97 |
3 x 1,5 | 78,72 | 30 x 0,26 | 7,6 | 124 |
4 x 1,5 | 96,00 | 30 x 0,26 | 8,2 | 166 |
5 x 1,5 | 114,24 | 30 x 0,26 | 9,0 | 192 |
7 x 1,5 | 147,84 | 30 x 0,26 | 9,8 | 245 |