SL 800 | Combined Composite Connection Cable with PUR Outer Sheath
Item descriptions
Application: | This cable is well suited for flexible use in industries such as industrial robots, cable chains or machine and plant engineering. It is used for high mechanical stress in dry, damp and wet locations as well as at low temperatures as a connection cable for the power supply and as a signal and data cable for the steering and control of motors. |
Construction: | 1.....very fine-stranded bare copper 2.....core insulation of thermoplastic polyester elastomer or polypropylene (PP) 3.....pair wise shielding of aluminium foil 4.....outer sheath of polyurethane (PUR), grey, oil and abrasion resistant, UV-resistant |
Standards: | in according with DIN VDE 0281 DIN EN 60228 class 6 (construction) |
Nominal voltage Uo/U | [V] | 600 / 1000 Volt | |
Test voltage | [V]AC | 4000 | |
Temperature range | in motion | -30°C till +80°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 7,5 |
Oil-resistant | standard | EN 60811-2-1 | |
Flammability | standard | EN 60332-1-2 |
Number of cores and nominal cross section mm² | Copper figure kg/km | Wire diameter mm | Overall diameter appr. mm | Weight appr. kg / km |
4 x 0,75 + 2x(2x0,34) | 65,28 | 0,16 | 9,7 | 125 |
4 x 1,50 + 2x(2x0,75) | 120,96 | 0,16 | 11,4 | 350 |
4 x 2,50 + 2x(2x0,75) | 159,36 | 0,16 | 13,7 | 244 |
4 x 4,00 + (2x0,75)+(2x1) | 219,84 | 0,16 | 15,6 | 352 |
4 x 6,00 + (2x0,75)+(2x1) | 299,52 | 0,21 | 18,3 | 473 |
4 x 10,00 + (2x0,75)+(2x1) | 453,12 | 0,21 | 22,1 | 685 |
4 x 16,00 + 2x(2x1) | 687,36 | 0,21 | 25,2 | 993 |
4 x 25,00 + 2x(2x1,5) | 1.032,96 | 0,21 | 30,0 | 1.740 |
4 x 35,00 + 2x(2x1,5) | 1.440,00 | 0,21 | 32,2 | 2.410 |