SL 806 C | Combined Composite Connection Cable with PVC Outer Sheath
Item descriptions
Application: | This cable is well suited for flexible use in machine and plant engineering. It is used for medium level mechanical stress in dry, damp and wet locations. It serves as a connection cable for the power supply and as a signal and data cable for the steering and control of motors. |
Construction: | 1.....very fine-stranded bare copper 2.....core insulation of polyvinylchloride (PVC) 3.....pair wise screened with aluminium foil 4.....paarweise screened with tinned copper drain wire 5.....wrapping of fine cotton binding 6.....screen of tinned copper braiding 7.....outer sheath of polyvinylchloride (PVC) |
Standards: | in according with DIN VDE 0281 DIN EN 60228 class 6 (construction) |
Nominal voltage Uo/U | Powerwire | [V] | 600 / 1000 Volt |
Controllwire | [V] | 300 / 500 Volt | |
Test voltage | Powerwire | [V]AC | 4000 |
Controllwire | [V]AC | 2000 | |
Temperature range | in motion | +5°C till +70°C | |
Operating temperature | short circuit | °C | 150 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 7,5 |
Flammability | standard | EN 60332-1-2 |
Number of cores and nominal cross section mm² | Copper figure kg/km | Wire diameter mm | Overall diameter appr. mm | Weight appr. kg / km |
4 x 0,75 + 2 x (2x0,34) | 125,76 | 0,16 | 11,5 | 171 |
4 x 1,50 + 2 x (2x0,75) | 179,52 | 0,16 | 13,8 | 256 |
4 x 2,50 + 2 x (2x0,75) | 230,40 | 0,16 | 16,2 | 394 |
4 x 10,00 + 2 x (2x1) | 600,00 | 0,21 | 23,5 | 854 |
4 x 16,00 + 2 x (2x1) | 865,92 | 0,21 | 26,5 | 1.152 |
4 x 25,00 + 2 x (2x1,5) | 1.257,60 | 0,21 | 30,0 | 1.672 |
4 x 35,00 + 2 x (2x1,5) | 1.678,08 | 0,21 | 34,2 | 2.116 |