E-AYY | PVC Insulated Cable with Aluminium Conductor

 
 

Item descriptions

Application: This power cable is suitable for fixed installations, preferably in cable ducts, indoors, outdoors, in water or underground if no mechanical damage is to be expected.
Construction:
1.....solid (SE) or stranded (RM/SM) aluminium wires
2.....core insulation of polyvinylchloride (PVC)
3.....PVC core covering or taping
4.....outer sheath of polyvinylchloride (PVC), black, UV-resistant
Information: short circuit temperature at core (max. 5 sec.) < =300mm² --> 160°C   > 300mm² --> 140°C
Standards: ÖVE K 23 and K 603 HD 603 S1 DIN EN 60228 class 1 and 2 (construction) HD 308 S2 (core identification)
Technical data:
Nominal voltage Uo/U [V] 600 / 1000 Volt
Test voltage [V]AC 4000
Temperature range in motion -  5°C till +70°C
fixed -20°C till +70°C
Bending radius single-core style x diameter 15
multi-core style x diameter 12
Flammability standard EN 60332-1-2
Number of cores and nominal cross section mm² Aluminium figure kg/km Overall diameter appr. mm Weight appr. kg / km Current carrying capacity ground A Current carrying capacity air A
1 x   25 RM 74 11 174 106 87
1 x   35 RM 103 12 209 127 107
1 x   50 RM 147 14 282 151 131
1 x   70 RM 206 16 363 185 166
1 x   95 RM 279 18 520 222 205
1 x 120 RM 353 19 557 253 239
1 x 150 RM 441 21 674 284 273
1 x 185 RM 544 24 826 322 317
1 x 240 RM 706 26 1.052 375 378
1 x 300 RM 882 29 1.282 425 437
1 x 400 RM 1.200 32 1.598 487 513
1 x 500 RM 1.510 36 2.022 558 600
1 x 630 RM 1.900 40 2.200 635 701
3 x 240/120 SM 2.470 55 4.215 364 338
Number of cores and nominal cross section mm² Aluminium figure kg/km Overall diameter appr. mm Weight appr. kg / km Current carrying capacity ground A Current carrying capacity air A
4 x 150 SE 1.764 45 2.594 275 246
4 x   25 RM 294 25 887 102 82
4 x   35 SM 412 26 796 123 100
4 x   50 SM 588 27 1.017 144 119
4 x   70 SM 823 30 1.312 179 152
4 x   95 SM 1.117 34 1.698 215 186
4 x 120 SM 1.411 40 2.459 245 216
4 x 150 SM 1.764 43 2.594 275 246
4 x 185 SM 2.176 50 3.777 313 285
4 x 240 SM 2.822 54 4.106 364 338
5 x   16 RM 235 22 675
5 x   25 RM 368 26 1.018 102 81
5 x   35 RM 515 30 1.316 121 99
5 x   50 SM 735 32 1.549 144 119
5 x   70 SM 1.071 37 2.021 179 152
5 x   95 SM 1.484 41 2.598 215 186
5 x 120 SM 1.764 47 3.201 245 216
5 x 150 RM 2.218 56 4.300 275 246
5 x 185 RM 2.736 62 5.350 313 285
5 x 240 RM 3.530 71 7.580 364 338

Title: E-AYY

Download PDF Data sheet

TOP

Tesla kabeli d.o.o.
Industrijska 20, 10431 Sveta Nedelja, Hrvatska

OIB: 75321357467
MB: 4081340

OTP banka d.d. - Split HR6524070001100185687 | SWIFT OTPVHR2X
Hrvatska poštanska banka d.d. - Zagreb: HR2823900011198007664 | SWIFT HPBZHR2X
KentBank d.d. – Zagreb HR5341240031199011634 | SWIFT KENBHR22
Erste&Steiermärkische Bank d.d. - Zagreb HR5024020061100674424 | SWIFT ESBCHR22

Tesla kabeli d.o.o.
Batajnički drum 10. deo br. 1, 11080 Zemun, Srbija

PDV: RS108828595
PIB: 108828595
MB: 21075680

AIK banka A.D. - Beograd RS35105000000280701248 | SWIFT AIKBRS22
OTP banka - Srbija A.D. Novi Sad RS35325960170006817238/ SWIFT: OTPVRS22
ERSTE BANK - A.D. Novi Sad RS35340000001101229969 / SWIFT: GIBARS22

office@teslacables.com