NAYY | PVC Insulated Cable with Aluminium Conductor

 
 

Item descriptions

Application: This power cable is suitable for fixed installations, preferably in cable ducts, indoors, outdoors, in water or underground if no mechanical damage is to be expected.
Construction:
1.....solid (SE) or stranded (RM/SM) aluminium wires
2.....core insulation of polyvinylchloride (PVC)
3.....PVC inner sheath (FM)
4.....outer sheath of polyvinylchloride (PVC), black, UV-resistant
Information: short circuit temperature at core (max. 5 sec.) < =300mm² --> 160°C   > 300mm² --> 140°C
Standards: DIN VDE 0276-603 HD 603 S1 DIN EN 60228 class 1 and 2 (construction) HD 308 S2 (core identification)

Technical data:

Nominal voltage Uo/U   [V] 600 / 1000 Volt
Test voltage   [V]AC 4000
Temperature range in motion   -  5°C till +70°C
  fixed   -20°C till +70°C
Bending radius single-core style x diameter 15
  multi-core style x diameter 12
Flammability standard   EN 60332-1-2
Number of cores and nominal cross section mm² Aluminium figure kg/km Overall diameter appr. mm Weight appr. kg / km Current carrying capacity ground A Current carrying capacity air A  
1 x   16 RE       49 11       161      
1 x   25 RM 74 11 174 106 87  
1 x   35 RM 103 12 209 127 107  
1 x   50 RM 147 14 282 151 131  
1 x   70 RM 206 16 363 185 166  
1 x   95 RM 279 18 520 222 205  
1 x 120 RM 353 19 557 253 239  
1 x 150 RM 441 21 674 284 273  
1 x 185 RM 544 24 826 322 317  
1 x 240 RM 706 26 1.052 375 378  
1 x 300 RM 882 29 1.282 425 437  
1 x 400 RM 1.200 32 1.598 487 513  
1 x 500 RM 1.510 36 2.022 558 600  
1 x 630 RM 1.900 40 2.200 635 701  
             
Number of cores and nominal cross section mm² Aluminium figure kg/km Overall diameter appr. mm Weight appr. kg / km Current carrying capacity ground A Current carrying capacity air A  
4 x   25 RE 294 27 887 102 82  
4 x   35 RE 412 29 796 123 100  
4 x   50 SE 588 31 1.017 144 119  
4 x   70 SE 823 34 1.312 179 152  
4 x   95 SE 1.140 40 1.698 215 186  
4 x 120 SE 1.440 42 2.459 245 216  
4 x 150 SE 1.764 51 2.594 275 246  
4 x 185 SE 2.176 54 3.777 313 285  
4 x 240 SE 2.822 60 4.106 364 338  
             
4 x   35 RM 412 29 796 123 100  
4 x   50 SM 588 31 1.017 144 119  
4 x   70 SM 823 34 1.312 179 152  
4 x   95 SM 1.140 40 1.698 215 186  
4 x 120 SM 1.440 42 2.459 245 216  
4 x 150 SM 1.764 51 2.594 275 246  
4 x 185 SM 2.176 54 3.777 313 285  
4 x 240 SM 2.822 60 4.106 364 338  
4 x 300 SM 3.528 63 5.800 419 400  
             
5 x   16 RM 245 25 858      
5 x   25 RM 383 29 1.214 102 81  
5 x   35 RM 536 32 1.453 121 99  
5 x   50 SM 781 35 1.855 144 119  
5 x   70 SM 1.094 40 2.351 179 152  
5 x   95 SM 1.484 45 3.071 215 186  
5 x 120 SM 1.875 49 3.631 245 216  
5 x 150 RM 2.218 58 4.800 275 246  
5 x 185 RM 2.736 62 5.445 313 285  
5 x 240 RM 3.530 71 6.950 364 338  

Title: NAYY

Download PDF Data sheet

TOP

Tesla kabeli d.o.o.
Industrijska 20, 10431 Sveta Nedelja, Hrvatska

OIB: 75321357467
MB: 4081340

OTP banka d.d. - Split HR6524070001100185687 | SWIFT OTPVHR2X
Hrvatska poštanska banka d.d. - Zagreb: HR2823900011198007664 | SWIFT HPBZHR2X
KentBank d.d. – Zagreb HR5341240031199011634 | SWIFT KENBHR22
Erste&Steiermärkische Bank d.d. - Zagreb HR5024020061100674424 | SWIFT ESBCHR22

Tesla kabeli d.o.o.
Batajnički drum 10. deo br. 1, 11080 Zemun, Srbija

PDV: RS108828595
PIB: 108828595
MB: 21075680

AIK banka A.D. - Beograd RS35105000000280701248 | SWIFT AIKBRS22
OTP banka - Srbija A.D. Novi Sad RS35325960170006817238/ SWIFT: OTPVRS22
ERSTE BANK - A.D. Novi Sad RS35340000001101229969 / SWIFT: GIBARS22

office@teslacables.com