LiYY | Electronic Control Cable
Item descriptions
Application: | To be installed in dry and humid rooms and used as a termination and connection cable in the control, measuring and signal technology. |
Construction: | 1.....fine-stranded bare copper 2.....core insulation of polyvinylchloride (PVC) 3.....outer sheath of polyvinylchloride (PVC), grey |
Information: | Peak operating voltage [V]: 0,14 mm² ... 350 Volt all others ... 500 Volt Test Voltage [VAC]: 0,14 mm² ... 800 Volt all others ... 1.200 Volt |
Standards: | adapted to DIN VDE 0812 DIN EN 60228 class 5 (construction) DIN 47100 or factory standard (core identification) |
Temperature range | in motion | -5°C till +50°C | |
fixed | -40°C till +80°C | ||
Bending radius | in motion | x diameter | 10 |
Flammability | standard | EN 60332-1-2 | |
Insulation resistance | min. | [MOhm/km] | 100 |
Number of cores and nominal cross section mm² | Copper figure kg/km | Cond. construction (appr. value) mm | Conductor loop resistance Ohm/km | Overall diameter appr. mm | Weight appr. kg / km |
2 x 0,14 | 2,69 | 18 x 0,10 | 138,0 | 3,2 | 12 |
3 x 0,14 | 4,03 | 18 x 0,10 | 138,0 | 3,4 | 15 |
4 x 0,14 | 5,38 | 18 x 0,10 | 138,0 | 3,6 | 17 |
5 x 0,14 | 6,72 | 18 x 0,10 | 138,0 | 3,9 | 22 |
6 x 0,14 | 8,06 | 18 x 0,10 | 138,0 | 4,2 | 25 |
7 x 0,14 | 9,41 | 18 x 0,10 | 138,0 | 4,2 | 26 |
8 x 0,14 | 10,75 | 18 x 0,10 | 138,0 | 4,5 | 29 |
10 x 0,14 | 13,44 | 18 x 0,10 | 138,0 | 5,2 | 35 |
12 x 0,14 | 16,13 | 18 x 0,10 | 138,0 | 5,6 | 43 |
16 x 0,14 | 21,50 | 18 x 0,10 | 138,0 | 6,1 | 52 |
18 x 0,14 | 24,19 | 18 x 0,10 | 138,0 | 6,9 | 65 |
21 x 0,14 | 28,22 | 18 x 0,10 | 138,0 | 6,9 | 79 |
24 x 0,14 | 32,26 | 18 x 0,10 | 138,0 | 7,6 | 89 |
30 x 0,14 | 40,32 | 18 x 0,10 | 138,0 | 8,0 | 106 |
2 x 0,25 | 4,80 | 14 x 0,16 | 75,5 | 3,8 | 25 |
3 x 0,25 | 7,20 | 14 x 0,16 | 75,5 | 4,0 | 29 |
4 x 0,25 | 9,60 | 14 x 0,16 | 75,5 | 4,3 | 31 |
5 x 0,25 | 12,00 | 14 x 0,16 | 75,5 | 4,7 | 38 |
Number of cores and nominal cross section mm² | Copper figure kg/km | Cond. construction (appr. value) mm | Conductor loop resistance Ohm/km | Overall diameter appr. mm | Weight appr. kg / km |
6 x 0,25 | 14,40 | 14 x 0,16 | 75,5 | 5,1 | 42 |
7 x 0,25 | 16,80 | 14 x 0,16 | 75,5 | 5,4 | 48 |
8 x 0,25 | 19,20 | 14 x 0,16 | 75,5 | 5,7 | 54 |
10 x 0,25 | 24,00 | 14 x 0,16 | 75,5 | 6,8 | 65 |
12 x 0,25 | 28,80 | 14 x 0,16 | 75,5 | 7,0 | 75 |
16 x 0,25 | 38,40 | 14 x 0,16 | 75,5 | 7,7 | 95 |
18 x 0,25 | 43,20 | 14 x 0,16 | 75,5 | 8,3 | 101 |
24 x 0,25 | 57,60 | 14 x 0,16 | 75,5 | 9,4 | 143 |
30 x 0,25 | 72,00 | 14 x 0,16 | 75,5 | 10,3 | 172 |
36 x 0,25 | 86,40 | 14 x 0,16 | 75,5 | 11,1 | 196 |
2 x 0,34 | 6,53 | 19 x 0,16 | 57,5 | 4,2 | 28 |
3 x 0,34 | 9,79 | 19 x 0,16 | 57,5 | 4,4 | 30 |
4 x 0,34 | 13,06 | 19 x 0,16 | 57,5 | 4,8 | 40 |
5 x 0,34 | 16,32 | 19 x 0,16 | 57,5 | 5,5 | 44 |
7 x 0,34 | 22,85 | 19 x 0,16 | 57,5 | 5,9 | 60 |
10 x 0,34 | 32,64 | 19 x 0,16 | 57,5 | 7,6 | 77 |
12 x 0,34 | 39,17 | 19 x 0,16 | 57,5 | 7,8 | 97 |
16 x 0,34 | 52,22 | 19 x 0,16 | 57,5 | 8,7 | 114 |
18 x 0,34 | 58,75 | 19 x 0,16 | 57,5 | 9,1 | 135 |
24 x 0,34 | 78,34 | 19 x 0,16 | 57,5 | 11,0 | 171 |
36 x 0,34 | 117,50 | 19 x 0,16 | 57,5 | 12,5 | 244 |
2 x 0,5 | 9,60 | 16 x 0,21 | 37,8 | 4,7 | 25 |
3 x 0,5 | 14,40 | 16 x 0,21 | 37,8 | 5,0 | 35 |
4 x 0,5 | 19,20 | 16 x 0,21 | 37,8 | 5,6 | 42 |
5 x 0,5 | 24,00 | 16 x 0,21 | 37,8 | 6,1 | 49 |
7 x 0,5 | 33,60 | 16 x 0,21 | 37,8 | 6,9 | 73 |
10 x 0,5 | 48,00 | 16 x 0,21 | 37,8 | 8,6 | 120 |
12 x 0,5 | 57,60 | 16 x 0,21 | 37,8 | 8,9 | 130 |
16 x 0,5 | 76,80 | 16 x 0,21 | 37,8 | 10,2 | 152 |
18 x 0,5 | 86,40 | 16 x 0,21 | 37,8 | 10,2 | 159 |
24 x 0,5 | 115,20 | 16 x 0,21 | 37,8 | 12,5 | 250 |
36 x 0,5 | 172,80 | 16 x 0,21 | 37,8 | 14,5 | 315 |
3 x 0,75 | 21,60 | 24 x 0,21 | 25,3 | 5,6 | 64 |
5 x 0,75 | 36,00 | 24 x 0,21 | 25,3 | 6,9 | 77 |